The common fault of electric heat pipe and its elimination method
First, electric heat pipe leakage
Cause:
1, not connected to the ground;
2, electric socket or power plug dirt too much
3. The circuit wire falls off and collides with the cup body
4, heat pipe (core) insulation damage
5. The heat pipe (core) is burned out and the cup body is short-circuited
6, improper cleaning, water infiltration
Treatment method:
1. Connect the ground wire as required
2. Clean the power socket or power plug and dry it
3, check the loose wire, re-weld
4. Repair or replace
5, replace the same specification heat pipe (core)
6, clean correctly, dry treatment
Second, the electric heat pipe does not heat
Cause:
1. Abnormal power supply or power failure
2. The fuse has been blown
3. The power cord plug is in poor contact with the electric socket, or the power cord conductor is disconnected
4. The lead or lead of the heat pipe (core) falls off
5, the heat pipe (core) burned
6, the temperature controller contact is poor contact or melting off
Treatment method:
1. Check the power supply and use it after normal operation
2. Replace the fuse of the same model
3. Repair or replace
4. Re-weld
5, replace the electric heat pipe (core) with the same specification
6. Repair or replace
Third, temperature control flange heat pipe, electric temperature control device failure
Cause:
1. The porcelain contact rod of the temperature controller is stuck by a foreign body
2, hot bimetal sheet deformation
3, dynamic and static contact fatigue, loss of elasticity, poor contact
4. The dynamic and static contacts are sticky and cannot be opened or closed
5, the dynamic and static contact plate fastening screws loose
Treatment method:
1, remove foreign bodies, hand press can move up and down flexibly
2, adjust the deformation, restore the original state and elasticity
3, adjust the Angle of the contact to restore its elasticity
4, grinding contact, if there is no effect to replace new products
5. Tighten again
Four, the fuse of the electric heat pipe is blown
Cause:
1, the diameter of the fuse is too small, the capacity is insufficient
2. Short circuit between power cord plug and electric socket
3. The primer or lead of the heat pipe falls off, causing short circuit
4, the heat pipe (core) burned out caused by short circuit
5, electric socket accumulation of dirt or carbonization caused short circuit
Treatment method:
1. Replace the appropriate fuse
2, repair or replace the power plug or electric socket
3. Reattach
4. Repair or replace
5. Remove dirt, repair or replace parts